What is Heat of compression ?
Energy Conservation by Heat of Compression type compressed air dryer is a breakthrough in compressed air drying technology. it is the most energy saving economical & cheapest equipment for making air dry. The hot air from the oil-free air Compressor at 120°C or higher temp, is used directly for regeneration of the desiccant bed in the compressed air dryer. After regeneration, this air is cooled down to 40°C in the water cooled after cooler and then it is dried in second tower. Thus the use of heaters is eliminated. For example. in the 6 + 6 Hrs. Cycle the hot air is fed for regeneration of desiccant bed for 4 Hrs. and for balance 2 Hr. a changeover takes place where the air is first cooled in an after cooler, then dried and before going to the outlet, cools the regenerated desiccant bed, thus bringing it down to ambient temperature. This cycle is reversed for the next 6 Hrs. where the Adsorber drying the air in the previous cycle goes for regeneration and vice versa.
There is considerable power saving in these heat of compression Air Dryers and the dew point is also better than the Refrigerated type of Compressed Air Dryers .Main Advantage of Heat of Compression Type Compressed air dryer is the energy conservation and heat recovery achieved which is being wasted in After cooler in the conventional air dryers is now used to reactivate the desiccant.
MODEL NO. | CAPACITY | PIPE LINE SIZE mm |
COOLING WATER REQT. LPM |
APPROX. OVERRALL DIMENSIONS | |||
M³/ HR | CFM | LENGHT mm |
WIDTH mm |
HEIGHT mm | |||
HOC-01 | 81.5 | 50 | 25 | 12 | 1400 | 1200 | 1800 |
HOC-02 | 122.7 | 75 | 25 | 18 | 1500 | 1200 | 1800 |
HOC-03 | 163.0 | 100 | 25 | 24 | 1600 | 1400 | 1800 |
HOC-04 | 244.5 | 150 | 40 | 36 | 1800 | 1500 | 2000 |
HOC-05 | 326.0 | 200 | 40 | 48 | 1800 | 1500 | 2000 |
HOC-06 | 489.0 | 300 | 50 | 72 | 2000 | 1500 | 2200 |
HOC-07 | 652.0 | 400 | 50 | 96 | 2000 | 1500 | 2200 |
HOC-08 | 815.0 | 500 | 65 | 120 | 2000 | 1800 | 2200 |
HOC-09 | 978.0 | 600 | 65 | 144 | 2200 | 1800 | 2400 |
HOC-10 | 1222.0 | 750 | 80 | 180 | 2400 | 1800 | 2400 |
HOC-11 | 1630.0 | 1000 | 80 | 240 | 2500 | 2000 | 2600 |
HOC-12 | 2037.0 | 1250 | 100 | 300 | 2500 | 2000 | 2800 |
HOC-13 | 2445 | 1500 | 100 | 360 | 2500 | 2000 | 3000 |
HOC-15 | 3260.0 | 2000 | 125 | 480 | 3000 | 2000 | 3000 |
HOC-16 | 4075.0 | 2500 | 125 | 600 | 3000 | 2000 | 3400 |
The above capacities are rated at an inlet temp. of 40°C., 7kg/ Cm2g Pr ( 0.7 Mpa ). and at an outlet dew point of (-) 40°C. at Atm. Pressure, Supply Voltage of 220 V-1 PH- 50 HZ or 415V-3PH-50 Hz.
Above data is only for estimation and can be changed without notice. For special systems and higher capacities contact us.
Important Limitation : Energy Saving Heat of Compression type air dryer can be used only with oil free air compressors.IFor cost comparison of operating of a Heat of Compression Type Air Dryers Vs. Heated Type /Heatless
/Refrigerated Type Air Dryers please clickhere.
OUR PRODUCT RANGES |
||
Air / Gas Dryers | Refrigerated Equipments | Other Products |
|
|
|
Storage Systems | Onsite Gas Generators | |
|
|
|
Spare Parts | ||
|
Areawise Associates | Product Profiles | Corporate Info | Exhibitions | Customers | Approvals |
| |
All Rights Reserved Mellcon Engineers Pvt Ltd. |